Level 2 Chimney Inspection

When something changes — a sale, a new appliance, a chimney fire — a Level 1 can't answer the new questions. A Level 2 adds a flue scan and accessible structure areas to do that.

A George & Sons technician running a video camera inspection from the firebox

A Level 2 inspection exists for a simple reason: sometimes the question isn't "is this familiar chimney still fine?" but "what condition is this chimney actually in, now that something has changed?" A Level 1's readily-accessible visual scope is built for the first question. The second — triggered by a sale, a system change, or an event that could have caused damage — needs a fuller look, and that's what a Level 2 provides.

What a Level 2 adds

A Level 2 includes everything a Level 1 covers, and then extends the examination in two important directions:

  • Accessible areas of the structure. We examine accessible portions of the attic, crawl space and basement where the chimney passes through, looking at how it interacts with the building — clearances to combustibles, signs of heat or water damage, and the condition of the chimney where it's normally out of sight.
  • A video scan of the flue interior. Using a specialized chimney camera, we view the inside of the flue along its length, documenting the liner's condition — cracks, gaps, spalling, deterioration and obstructions that a readily-accessible visual check can't fully reveal.

Crucially, a Level 2 is still non-invasive. It reaches further using access and technology, but it doesn't require removing or opening any part of the chimney or structure. That line — looking further without opening anything up — is exactly what separates it from a Level 3.

When a Level 2 is required

The national standard ties a Level 2 to specific circumstances, and they share a theme: something has changed, or something has happened.

A Level 2 is the appropriate inspection when: - a property is being sold or transferred; - the system has changed — a new appliance, a different fuel, a relined or altered flue; - an event may have caused damage — a chimney fire, a serious storm, an earthquake, an impact, or a suspected operating malfunction.

In each case, the assumptions a Level 1 relies on no longer hold, and the fuller scope is what answers the new question honestly.

The situations in practice

A home sale. A buyer inherits a chimney with no personal history of how it's been used or maintained. A Level 2 — offered specifically as a real estate chimney inspection — gives both parties a documented, flue-interior picture of condition rather than an assumption.

A change of appliance or fuel. Switching from an open fireplace to an insert, from wood to gas, or installing a new stove changes what the flue has to do. A flue that suited the old setup may be the wrong size or condition for the new one, and the Level 2 confirms suitability before you depend on it.

After a chimney fire or major event. Heat from a chimney fire can crack flue tiles in ways invisible from the firebox, and the camera scan is how that's found. This is important enough to treat on its own — see post-fire chimney inspection — and the rule is simple: don't use the chimney until it's been inspected.

Where a Level 2 can lead

Most Level 2 inspections are complete in themselves — they answer the question and inform whatever repair, if any, is warranted. Occasionally, though, a Level 2 reveals evidence of a hidden hazard that genuinely can't be evaluated without deeper access. That's the specific trigger for a Level 3, which may involve opening part of the structure. A Level 3 is never a routine upsell from a Level 2 — it's a targeted response to a specific, documented concern, and we'd explain precisely what that concern is before recommending it.

Honest use of the camera

The flue scan is a powerful tool, and we use it fully — but we're also clear about what it is. A camera documents what the flue looks like along its line of sight; it's one input to the inspection, not a replacement for the whole evaluation. A thorough Level 2 combines the scan with the accessible structural examination and professional judgment. More on the tool itself under video inspection.

What the structural view adds

The flue scan gets most of the attention, but the accessible structural examination is where a Level 2 often earns its keep. Following the chimney through the attic, crawl space and basement — wherever it's reachable — lets us see the parts of the system that live behind the finished surfaces of the home. That's where we check how the chimney interacts with the building: the clearance between the chimney or connector and combustible framing, signs of past heat exposure like scorching or discoloration, and evidence of water tracking down the chimney and into the structure.

These are findings a readily-accessible Level 1 simply can't make, and they matter. A chimney can look perfectly sound from the firebox and the yard while hiding a clearance problem or water damage in the attic that only a Level 2 would catch. For a home sale in particular, this structural view is part of what makes the inspection worth more than a surface check — it's looking at how the whole system sits within the house, not just at the flue in isolation. When the two halves of a Level 2 — the internal scan and the structural examination — are combined, you get a genuinely fuller picture than either alone.

What affects the scope

A Level 2 varies with the type and layout of the chimney, how accessible the attic, crawl and basement runs are, the flue's configuration, and what the scan and examination reveal as they progress. The triggering situation — sale, change or event — also shapes what we focus on. We confirm the scope with you before starting.

Preparing for the visit

  • Let the chimney and appliance go cold beforehand.
  • Clear access to the fireplace, and to the attic, basement or crawl space where the chimney runs.
  • Tell us why a Level 2 is needed — sale, system change, or an event — and share any history, including a suspected chimney fire or recent storm.

When the situation has moved beyond "business as usual," the Level 2 is the inspection that meets it — looking as far as a non-invasive examination can, and telling you clearly where your chimney stands.

Questions about level 2 chimney inspection

What's added in a Level 2 compared to a Level 1?

A Level 2 includes everything in a Level 1, plus accessible areas in the attic, crawl space and basement where the chimney passes through, and a video scan of the flue interior to examine the liner along its length. It still doesn't require opening or demolishing any part of the structure — that's a Level 3 — but it looks considerably further than the readily-accessible Level 1 scope.

When is a Level 2 required?

The standard associates a Level 2 with specific situations: the sale or transfer of a property; a change to the system such as a new appliance, a different fuel, or a relined or altered flue; and after an event that may have caused damage — a chimney fire, a serious storm, an earthquake, or a suspected operating malfunction. If any of those apply, a Level 2 is the appropriate inspection.

Why does selling a house trigger a Level 2?

Because a buyer is inheriting a system they have no history with, and continued-use assumptions don't apply. A Level 2 gives a fuller, documented picture of condition — including the flue interior — which is what both parties need to make an informed decision. We offer this as a real estate chimney inspection.

Does a Level 2 always include a camera scan?

A video scan of the flue interior is a defining part of a Level 2, where access and conditions allow. The camera documents the liner's condition along its length — cracks, gaps, deterioration — which a readily-accessible visual check can't fully capture. That scan is a tool within the inspection, not a substitute for the whole evaluation.

I had a chimney fire — is a Level 2 enough?

A Level 2 is the right starting point after a chimney fire, because the flue scan can reveal cracked or damaged tiles caused by the heat. If the Level 2 finds evidence of a hidden hazard that can't be fully evaluated without deeper access, it may lead to a Level 3. Either way, don't use the chimney until it's been inspected — see our post-fire inspection page.

Do I need a Level 2 if I'm switching from wood to gas?

Changing the appliance or fuel is one of the situations a Level 2 is made for. A flue that was fine for one appliance may be the wrong size or condition for another, and the venting requirements differ. A Level 2 confirms the chimney is suitable for the new setup before you rely on it.

Will a Level 2 require opening up my chimney?

No. A Level 2 is still a non-invasive inspection — it uses accessible areas and a camera, but it doesn't involve removing or demolishing any part of the chimney or structure. If the Level 2 suggests a hidden problem that genuinely can't be evaluated otherwise, that's when a Level 3 enters the picture, and we'd explain exactly why.

How is the flue scan actually done?

We pass a specialized chimney camera through the flue to view the interior along its line of sight, documenting the liner's condition. It's effective for what it can see, though like any camera it's limited to its line of sight and the access available — which is why it's part of a broader inspection rather than the whole of it.

Works with

Related services

Chimney and fireplace problems rarely sit in isolation. These related services often come up alongside this one.

A George & Sons technician running a video camera inspection from the firebox Inspections

Chimney Inspections

Provide a decision guide to inspection scope; distinguish an inspection finding, a camera view, an estimate, and a cleaning visit.

View service →
A brick chimney with a hip-style metal cap on a tile roof Inspections

Level 1 Chimney Inspection

Explain readily accessible inspection scope and the situations where a routine unchanged-system evaluation may be appropriate; do...

View service →
A chimney crown with two clay flue tiles exposed before cap installation Inspections

Level 3 Chimney Inspection

Explain targeted access to concealed areas when indicated; address authorization, scope and repair of opened areas rather than...

View service →
A George & Sons technician running a video camera inspection from the firebox Inspections

Chimney Camera / Video Inspection

Explain what camera imagery can document, line-of-sight limitations, and why a camera scan alone does not replace the full...

View service →
A brick chimney with a sealed crown and two flue caps Inspections

Real Estate Chimney Inspection

Address buyer/seller timing, the difference from a general home inspection, documented findings, and the need to select the actual...

View service →
Heavy creosote and soot buildup around a flue opening before cleaning Inspections

Post-Fire Chimney Inspection

Discuss evaluation after a suspected chimney fire, documenting conditions before reuse, and why appearance from the room cannot...

View service →

All 76 services →

Serving Missouri, Illinois & Kansas

Ready when you are — available 24/7

Reach the office nearest you, or send your details and we’ll plan the next step.

St. Louis · 314-876-8048 Kansas City · 816-683-1099 Request service

Request Service Call us