A pellet stove is really a small machine — motors, a feed auger, fans, igniter, and a control board all working together. When one part fails, the stove stops, and the fix depends on which part.

Close view of the burn pot flame inside a pellet stove

A pellet stove is a different animal from a wood stove, and the difference is that it's partly a machine. Where a wood stove simply holds a fire, a pellet stove runs on an orchestra of components — a motor-driven auger feeding fuel, an igniter lighting it, fans managing the air and the heat, sensors watching conditions, and a control board coordinating the whole performance. That sophistication is what gives a pellet stove its steady, thermostat-like convenience, and it's also what gives it more ways to fail. Pellet stove repair is largely about diagnosis: identifying which of those components has stopped doing its job, because the fix is entirely different depending on the answer.

Why it's more complex

It's worth understanding the machine to understand the repair. A pellet stove's main systems are:

  • The feed system — the hopper and the auger motor that feeds pellets into the burn pot at a controlled rate.
  • The ignition — the igniter element that lights the pellets.
  • The fans — a combustion/exhaust fan managing burning and venting, and a convection fan distributing heat.
  • The controls and sensors — the board and the sensors that monitor and coordinate everything.

A wood stove has none of this. So a pellet stove can fail in distinctly mechanical and electronic ways — a worn motor, a burned-out igniter, a failing fan, a bad sensor, a control fault — each a separate diagnostic path. The symptom tells us which path to follow.

The "won't start" problem

A no-start is one of the most common calls, and it spans several systems:

  • The igniter has failed (it's a wear item that heats every start).
  • The auger isn't feeding — jammed, or a failed motor.
  • The hopper is empty or jammed.
  • A sensor is preventing startup.
  • A control or power issue.

The specific behavior narrows it fast: does the stove try to feed pellets? Does the igniter spark or glow? Does it throw an error code? We watch what it actually does rather than guessing, because a no-start from a bad igniter and a no-start from a jammed auger are completely different repairs.

The crucial question: dirty, or broken?

This is the single most important diagnostic distinction in pellet stove repair, so we treat it carefully:

Ash and clinker buildup restricting airflow is a very common cause of shutdowns and faults — and that's resolved by a thorough cleaning, not a repair. But if the stove still shuts down after it's genuinely clean, the cause is likely a failing component — a sensor, a fan, the igniter, or a control issue — and that's a repair.

We don't assume a shutdown is one or the other. Cleaning a stove that has a bad sensor won't fix it; replacing a sensor on a stove that's just clogged is wasteful. So we determine which it actually is. Often a service visit starts with a deep cleaning of the hidden passages and then diagnoses whatever remains — which neatly separates the "it was just dirty" cases from the genuine repairs.

The feed system and the auger

The auger is the heart of a pellet stove's control — a motor-driven screw that feeds pellets into the burn pot at a regulated rate, which is how the stove sets its output. It fails when the motor wears or burns out, when pellets or debris jam it, or when a control problem throws off its timing. The symptoms are a stove that isn't feeding (no fuel reaching the fire) or feeding erratically. A jammed auger sometimes just needs clearing; a failed motor needs replacement with the correct part.

The igniter and the fans

The igniter heats up on every start to light the pellets, so it's a wear item that eventually burns out. A failed igniter is a common, well-defined repair — and while some stoves allow manual lighting as a stopgap, replacing the igniter restores proper automatic operation.

The fans do two different jobs: the combustion/exhaust fan manages burning and pushes exhaust out the vent (a performance and safety matter), while the convection fan distributes heat into the room. Noise, reduced airflow, or shutdowns can point to a fan, and we identify which one and whether it needs cleaning or replacement.

Model-specific parts

Augers, igniters, fans, sensors and control boards are designed for specific makes and models, with the right specifications and fit. Using the correct parts for your unit is essential for proper, safe operation — a generic substitute may not perform correctly or integrate with the controls. Having your make and model lets us source the right components, which is why we ask for it. On a stove that's part machine, the right parts aren't optional.

What affects the scope

Pellet stove repair scope depends on which component has failed, whether the issue is cleaning or a genuine part failure, the make and model and parts availability, and access. Clearing a jam or replacing an igniter is a defined job; an auger motor, a control board, or a multi-component fault is more involved. Diagnosis — including sorting dirty from broken — comes first.

Preparing for the visit

  • Describe exactly what happens — won't start, shuts down, won't feed, error codes, noise.
  • Try the owner basics first: clean the burn pot and ash pan, check the hopper.
  • Have the make and model ready for sourcing parts.
  • Let the stove cool and unplug it before we service it.

A pellet stove's complexity is the price of its convenience, and when it acts up, the answer is rarely "just clean it" or "just replace a part" — it's figuring out which. Diagnose the actual failed component, sort the dirty-versus-broken question honestly, and repair it with the right parts, and the steady, set-and-forget warmth you bought the stove for comes right back.

Questions about pellet stove repair

Why is a pellet stove more complex than a wood stove?

Because it's partly electronic and mechanical. A pellet stove uses an auger motor to feed pellets from the hopper into the burn pot, an igniter to light them, combustion and convection fans to manage airflow and distribute heat, sensors to monitor conditions, and a control board to coordinate it all. A wood stove has none of that — it just holds a fire. So a pellet stove can fail in ways a wood stove can't: a motor, a fan, the igniter, a sensor, or the board, each a distinct diagnostic path.

My pellet stove won't start. What could it be?

Several things: the igniter (the element that lights the pellets) may have failed, the auger may not be feeding pellets, the hopper may be empty or jammed, a sensor may be preventing startup, or there may be a control or power issue. A no-start has multiple possible causes across the feed, ignition, and control systems, which is why we diagnose which one has actually failed rather than guessing. The specific startup behavior — does it try to feed, does it spark, does it throw an error — narrows it down.

The stove keeps shutting down. Is that an electronic problem or just dirty?

It can be either, and telling them apart is the whole point. Ash and clinker buildup restricting airflow is a very common cause of shutdowns — and that's resolved by a thorough cleaning. But if the stove still shuts down after it's genuinely clean, the cause is likely a failing component — a sensor, a fan, the igniter, or a control issue — which is a repair, not a cleaning. We don't assume a shutdown is one or the other; we determine which, because cleaning a stove that has a bad sensor won't fix it, and replacing a sensor on a stove that's just clogged is wasteful.

What does the auger do, and how does it fail?

The auger is a motor-driven screw that feeds pellets from the hopper into the burn pot at a controlled rate — it's how the stove regulates its output. It can fail if the motor wears out or burns out, if pellets or debris jam it, or if a control problem affects its timing. Symptoms include the stove not feeding pellets (no fuel reaching the fire) or feeding erratically. A jammed auger sometimes just needs clearing; a failed motor needs replacement.

My igniter stopped working — can I still use the stove?

Some pellet stoves allow manual lighting if the automatic igniter fails, but it's inconvenient and not ideal, and the igniter is a replaceable component. Igniters are wear items — they heat up every start and eventually burn out — so a failed igniter is a common, well-defined repair. Rather than living with manual lighting indefinitely, replacing the igniter restores normal automatic operation. We use the correct igniter for your model.

Why do the fans matter?

A pellet stove has (typically) two fans doing different jobs: a combustion/exhaust fan that manages the air for burning and pushes exhaust out the vent, and a convection fan that blows heated room air out to warm your space. A failing combustion fan affects how the stove burns and vents — a performance and safety matter — while a failing convection fan affects heat distribution. Noise, reduced airflow, or shutdowns can point to a fan, and we identify which fan and whether it needs cleaning or replacement.

Should I clean it before calling for a repair?

Owner cleaning — emptying the burn pot and ash pan, clearing clinker — is always worth doing and sometimes resolves airflow-related faults on its own. If the stove still misbehaves after you've cleaned what you can reach, then it's time for a repair (or a thorough service cleaning that reaches the hidden passages). We're happy to do both; often a service visit includes a deep cleaning and then diagnoses whatever remains. Starting with the basics you can do yourself never hurts.

Are pellet stove parts specific to the model?

Yes. Augers, igniters, fans, sensors and control boards are designed for specific pellet stove makes and models, with the right specifications and fit. Using the correct parts for your unit is essential for proper, safe operation — a generic substitute may not perform correctly or integrate with the controls. Having your make and model lets us source the right components, which is why we ask for it.

Works with

Related services

Chimney and fireplace problems rarely sit in isolation. These related services often come up alongside this one.

A freestanding pellet stove with the flame visible Cleaning

Pellet Stove Cleaning

Discuss ash accumulation in appliance passages and pellet venting; differentiate routine owner tasks from service access to hidden pathways.

View service →
A freestanding pellet stove with the flame visible Installations

Pellet Stove Installation

Discuss appliance location, electric supply, vent routing/termination and maintenance access according to the selected manufacturer...

View service →
Glowing coals inside a wood-burning firebox Fireplace

Wood Stove Repair

Address door/gasket, baffle, firebrick and connected-system condition within manufacturer requirements, without merging appliance...

View service →
A fireplace insert installed in a stone-faced fireplace Fireplace

Fireplace Insert Repair

Identify fuel, make/model, venting and component symptoms; distinguish insert appliance repair from damage in the surrounding...

View service →
A metal flue cap and storm collar on a factory-built chimney Related

Gas Appliance Chimney & Venting Services

Focus on the chimney/vent serving an appliance, compatibility and observed venting concerns; do not imply general furnace, boiler...

View service →
A George & Sons technician running a video camera inspection from the firebox Inspections

Chimney Inspections

Provide a decision guide to inspection scope; distinguish an inspection finding, a camera view, an estimate, and a cleaning visit.

View service →

All 76 services →

Serving Missouri, Illinois & Kansas

Ready when you are — available 24/7

Reach the office nearest you, or send your details and we’ll plan the next step.

St. Louis · 314-876-8048 Kansas City · 816-683-1099 Request service

Request Service Call us