Available 24/7 St. Louis 314-876-8048 Kansas City 816-683-1099
George & SonsChimney Services

Installations & upgrades

Chimney Chase Cover Installation

A chase cover is the custom metal roof for a framed chimney chase. Installing one right is a measuring job as much as a metal job — it has to fit, shed water, and seal where the pipe comes through.

A black chase cover and cap installed on a sided chimney chase

A framed chimney chase — the boxed, sided enclosure that conceals a factory-built metal chimney — is essentially a small building sitting on your roof, and like any building it needs a sound roof of its own. That roof is the chase cover: the metal lid on top that keeps water out of the entire wood-framed enclosure. Installing a chase cover well is a precise job, equal parts measuring and metalwork, because the cover has to fit the specific chase exactly, shed water reliably, and seal cleanly where the flue pipe passes through. Get those right and the chase stays dry for years; get them wrong and you've installed a leak.

What a chase cover does, and why it must be right

The chase cover is the water barrier for a wood-framed structure, which raises the stakes:

The cover keeps water out of the entire chase — a wood-framed enclosure that, if it takes on water, develops rot and structural damage, not just surface problems. The framing inside depends entirely on the cover doing its job.

That dependency is why a chase cover isn't a place to cut corners. A failed or poorly made cover doesn't just leak a little; it lets water into a structure that can't take it, with hidden consequences. A properly installed cover is cheap insurance against expensive framing damage.

Measured and made to fit

A good chase cover is custom work:

We take the dimensions of the chase top and the location and size of the flue penetration, and the cover is fabricated to fit — with the right overhang, a water-shedding slope or cross-break, a drip edge, and a properly sized opening where the pipe passes through. It's essentially a tailored piece of sheet-metal work for your specific chase. The alternative — an off-the-shelf lid that approximately fits — just leaks in new places, because a chase cover that doesn't fit precisely can't seal and shed water the way the job requires. Fit is foundational.

The two features that prevent failure

The two things that kill chase covers are rust and ponding, and a well-made cover is specifically designed to defeat both:

  • Material. Stainless steel resists rust far better than the galvanized steel that failed on so many original installations, and lasts much longer (copper and aluminum are also options). The durable material addresses the rust.
  • Shape. A slope or cross-break makes water run off to the edges and drip clear via the overhang, rather than ponding in the middle where standing water accelerates corrosion. The water-shedding shape addresses the ponding.

A flat galvanized cover is practically engineered to fail; a sloped stainless one is engineered to last. Building in both from the start is the whole point of a quality installation.

The cover and the cap, together

A complete installation addresses two parts that work as a pair:

  • The chase cover — the flat lid over the whole chase top.
  • The cap — the rain cap over the flue pipe that penetrates the cover (see cap installation).

Installing a cover without attending to the pipe penetration and the cap would leave water a way in at the one spot the cover has to be opened. So a proper job includes both — the cover protecting the chase, the cap protecting the flue.

Sealing the penetration

That pipe penetration deserves its own attention, because it's the critical seal:

The opening is sized for the flue pipe, and the junction is sealed appropriately — often with a storm collar and suitable high-temperature sealant for the listed system — so water can't follow the pipe down into the chase. A beautifully made cover that leaks at the pipe penetration hasn't solved the problem. Getting this seal right is as important as the cover itself, and it connects directly to storm collar repair, which addresses exactly this junction. We treat the penetration as the make-or-break detail it is.

New cover, or replacing a failed one

Whether you're replacing a rusted, ponding original or there's no sound cover at all, the installation is the same careful process: measure, fabricate, fit, and seal a correctly sized, sloped, durable cover. One caveat — if the old cover's failure has already let water damage the chase framing or siding, we'll flag that, since it may need addressing too (see chase repair). And before assuming the cover is your leak source, we confirm where the water's actually getting in — the cover, the siding, the flashing, or the penetration — so the installation solves the real problem.

What affects the scope

Chase cover installation scope depends on the size of the chase, the number and position of flue penetrations, the material chosen, the chimney's height and access, and whether existing water damage to the chase also needs attention. A standard single-flue cover is a defined job; a large chase, multiple penetrations, or accompanying framing repair is more involved.

Preparing for the visit

  • Note the signs that brought you here — rust streaks, pooling on the cover, interior chase dampness.
  • Mention how long you've seen the problem; long-standing water may mean framing to check.
  • Tell us if you know whether there's existing damage to the chase.
  • Clear access to the chimney chase and roof.

A chase cover is the custom roof your framed chimney needs — and installing one right is about fit, water-shedding shape, durable material, and a clean seal at the pipe. Done that way, it keeps the wood-framed chase dry for the long haul, protecting both the metal chimney it conceals and the structure it's built from.

Questions about chimney chase cover installation

What is a chase cover, and which chimneys need one?

A chase cover is the metal lid on top of a framed chimney chase — the boxed, sided enclosure that houses a factory-built metal chimney. Any chimney with a framed chase (rather than masonry) needs a chase cover as its top water barrier. It's the cover's job to keep water out of the entire wood-framed enclosure, which is why getting it right matters so much — the framing inside depends on it.

How is a chase cover sized and made?

It's measured and fabricated to your specific chase. We take the dimensions of the chase top and the location and size of the flue penetration, and the cover is made to fit with the right overhang, a water-shedding slope or cross-break, a drip edge, and a properly sized opening where the flue pipe passes through. It's essentially a custom piece of sheet-metal work tailored to your chase — not an off-the-shelf lid that approximately fits, which just leaks in new places.

What material should a new chase cover be?

Stainless steel is the preferred choice — it resists rust far better than the galvanized steel that failed on so many original installations, and it lasts much longer. Copper and aluminum are also options. Since the most common chase cover failures are rust and ponding, a stainless cover formed to shed water solves both problems at the source. Spending on a durable, properly shaped cover is the difference between installing one once and replacing it repeatedly.

Why does the cover need a slope or cross-break?

To shed water instead of letting it pond. A flat chase cover collects water in the middle, and standing water accelerates corrosion until the cover rusts through and leaks — that's exactly how so many original covers failed. A proper cover is formed with a slope or a cross-break (a raised ridge) so water runs off to the edges and drips clear via the overhang. The water-shedding shape is one of the most important features of a well-made cover, and a flat one is practically designed to fail.

What's the difference between the chase cover and the cap?

They're separate parts that work together. The chase cover is the flat lid over the whole chase top; the cap (or rain cap) sits over the flue pipe that penetrates the cover. A complete installation addresses both — a properly made, sloped cover with a correctly sealed penetration, plus an appropriate cap over the pipe. The cover protects the chase; the cap protects the flue. Installing a cover without attending to the pipe penetration and cap would leave water a way in. See cap installation.

How is the penetration where the pipe comes through sealed?

Carefully, because it's the one spot a cover has to be opened. The opening is sized for the flue pipe, and the junction is sealed appropriately — often with a storm collar and suitable high-temperature sealant for the listed system — so water can't follow the pipe down into the chase. Getting this seal right is critical; a beautifully made cover that leaks at the pipe penetration hasn't solved the problem. This connects to storm collar repair, which addresses exactly that seal.

Can you install a chase cover if mine is failing or missing?

Yes — whether you're replacing a rusted, ponding original or there's no sound cover at all, we fabricate and install a correctly sized, sloped, durable cover. If the old cover's failure has already let water damage the chase framing or siding, we'll flag that, since it may need addressing too — see chase repair. The installation itself is the same careful measure-fabricate-fit-seal process regardless, aimed at a cover that keeps the chase dry for the long term.

Will a new chase cover stop my chase from leaking?

If the cover is the leak source, yes — a properly made and sealed cover stops water entering through the top of the chase. But a chase can also take water through the siding, the flashing where it meets the roof, or the pipe penetration. So we confirm where the water's actually getting in rather than assuming the cover. If it's the cover, installation solves it; if it's the siding or flashing, that's a different repair, and we'll identify which it is.

Works with

Related services

Chimney and fireplace problems rarely sit in isolation. These related services often come up alongside this one.

A large stainless chase cover installed over a wide stone chimney Chimney

Chase Cover Repair & Replacement

Explain the metal lid over a framed chase, ponding/rust/seams and penetrations; assess condition before sealing or replacing and...

View service →
Video Installations

Chimney Cap Installation

Explain single-/multi-flue or custom fit, attachment and component compatibility; distinguish a new cap from repairing an existing...

View service →
A black chase cover and cap installed on a sided chimney chase Chimney

Chimney Chase Siding & Trim Repair

Explain the framed exterior enclosure and water-damaged cladding/trim; distinguish enclosure repair from the listed chimney/vent...

View service →
A brick chimney with a sealed crown and a new black cap Chimney

Chimney Flashing Repair

Focus on the roof-to-chimney junction, step/counterflashing where applicable, and diagnosis that distinguishes roofing interfaces...

View service →
A black chase cover and cap installed on a sided chimney chase Chimney

Metal Chimney & Vent Pipe Repair

Discuss corrosion, connection integrity, supports and system listing; do not mix unrelated pipe brands/components or treat sealant...

View service →

All 76 services →

Serving Missouri, Illinois & Kansas

Ready when you are — available 24/7

Reach the office nearest you, or send your details and we’ll plan the next step.

St. Louis · 314-876-8048 Kansas City · 816-683-1099 Request service

Request Service Call us